CO1_2018

COMMENT KEYWORDS Aminocarbonylation, continuous-flow, kinetics. Chimica Oggi - Chemistry Today - vol. 36(1) January/February 2018 27 BIBL IOGRAPHY Synthesizing compounds which contain the carbonyl group, a key building block functional group was herein studied, where palladium-catalyzed aminocarbonylation of aromatic bromides in continuous flow systems was illustrated. This is an example of the significantly fewer two-phase gas-liquid reaction studies. The employment of continuous flow technologies in handling biphasic systems was demonstrated, enabling control over reaction time, temperature and pressure due to the small size of microreactors. This study was highly suitable to run under flow conditions because the reaction involved the use of a gas, carbon monoxide. This is because the small size of the continuous flow reactor channels allows high temperature and pressure to be routinely applied. When biphasic gas-liquid reactions are run in batch systems, expensive and specialized equipment is required, and there are many difficulties associated. On-line automated screening using ReactIR and off-line GC were used to monitor during the optimization and kinetics study of this continuous biphasic system. The use of both microreactors and on-line ReactIR allowed the reaction parameters to be easily controlled with minimum operator intervention. ReactIR is ideally suitable to use in biphasic gas-liquid systems because IR is not affected by formation of gas bubbles. When using in-line IR for analysis, unique IR bands of the starting material and products need to be identified so that they can be followed throughout the reaction. In this experiment however, no single peak could be used to easily monitor the formation of the product and consumption of the reagents. This is because both products: mono amide and α -keto amide possess characteristic amide IR-absorption bands that overlap. The starting material, p-bromobenzonitrile however, was difficult to monitor because the fingerprint spectra has very few characteristic bands. Qualitative analysis could have however been difficult but with the help of the built-in software of the system quantitative analysis was achieved. The effect of temperature, pressure and reagent molar ratio on product selectivity was clearly illustrated in these experiments. Use of both silicon microreactors and packed bed tubular reactors successfully demonstrated the kinetics and chemistry involved in carbonylation of aromatic bromide as there was correlation between results obtained when reactions were separately run in these microreactors. It was shown using both systems that pressure had a significant effect on product formation, where increase in pressure resulted in a decrease in overall conversion as the palladium catalyst would have been contaminated. Reaction temperature was shown to have an effect on product ratio. This was explained by the change in rate determining steps. This experiment clearly illustrated the importance of understanding kinetics of a biphasic gas-liquid system. The results satisfactorily illustrated how real-time in- line IR can be used principally for product monitoring during biphasic gas-liquid continuous flow reactions, giving valuable insight into reaction mechanisms and complex kinetics parameters. * Moore J.S, Smith C.D & Jensen K.F. Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Published online Feb 12, 2016. http://pubs.rsc.org/en/ content/articlepdf/2016/re/c6re00007j

RkJQdWJsaXNoZXIy MTY5Njg=