CO1_2018

COMMENT A typical chemical synthesis involves a sequence of multiple reactions with work-up between a precedent and successive steps. As it is known, extraction is considered the first step of the purification of a crude mixture. Typical work describing microchemical synthesis has been limited to a single reaction step (1) , multiple reaction steps without any intermediate work-up (2), multiple steps with precipitation and consequent solid capture (3), or off-line work-up. The paper cited above is an elegant example of the potential of micro-reactors in multi-step synthesis with in-line purification mediated by an integrated micro-separator. The authors choice of carbamates, themselves active biological compounds and useful building blocks, is a good example as their synthesis leads to the formation of hazardous intermediates (azide and isocyanate), and is difficult to scale up using conventional batch methods. Moreover, in batch mode, the azide is typically gently heated to temperatures not much beyond the decomposition point to avoid uncontrolled release of energy (4). The authors, performing the above describe reaction, took full advantage of continuous flow conditions: consumption of the intermediates in situ increasing the safety of the process, excellent heat transfer and chemical inertness using glass-coated silicon based micro-reactors, possibility of higher temperatures reducing the reaction time to obtain a complete conversion of the desired product and in-line purification extraction mediated without interruption of the flow. Solvent compatible micro-reactors combined with extraction systems allow continuous multistep synthesis from nanoliter to milliliter quantities and offer the possibility to quickly scale up the process to reach industrial scale. Moreover, this methodology avoids the use of precipitation and solid-phase capture agents as well as immobilized agents for scavenging reactive species, and it reduces the cost and the need of replacing/regenerating the solid phase. The basic principle of the liquid-liquid extractor described by Jensen and co- workers is the surface tension forces between the immiscible fluids instead of gravity as presented by Ley an co-workers. By exploiting the laminar flow features of micro-fluids devices, extraction happened by contacting of immiscible liquids in concurrent or counter-current flow (5). Even though these systems offer the potential for more than one equilibrium extraction stage, often modest separation due to low ratios of interfacial surface to micro-channel volume was observed (6). Phase separation in these systems is achieved by a small interfacial area to preserve the capillary pressure to balance the imposed driving pressure. Although systems using selective wetting of expanded porous materials and related phenomena have been used to separate aqueous and organic biphasic mixtures (7), their operation often requires quite careful control of the pressure differential across the membrane, placing limitation on their use. Additionally such system do not easily allow separation of immiscible organic liquid pairs (MeCN-Hexane, fluorous-non-fluorous) (8), and their life span is strictly related to the degradation of the coating membrane and its gradual dissolution in the flowing solvent or its susceptibility to chemical attacks. On the other hand, the versatility of this micro-devices was highlighted by not only the possibility of a liquid-liquid extraction but also a separation of gas-liquid phase as described in the carbamate synthesis. Instead, the replacement of the second micro-extractor with an open vial lead to have an unpressurized system and, on the other side, it requires the use of three different syringe pumps making the experimental set up bulkier and more expensive than the active pressure-drive system. The novelty of this system is the continuous multi-step synthesis with “in between purification via extraction” with the concurrent synthesis of three different compounds. This process could be expanded to a number of different compounds, and the described continuous operation mode could be scaled up by increasing the run time or the number of concurrent systems. 1. V. Hessel, H. Lowe Chem. Eng. Technol. 2005, 28, 267-284.; P. Watts, C. Wiles Chem. Eng. Technol. 2007, 30, 329-333; A. J. deMello Nature 2006, 442, 394-402. 2. H. Usutani, Y. Tomida, A. Nagaki, H. Okamoto, T. Nokami, J-i Yoshida J. Am. Chem. Soc. 2007, 129, 3046-3047; D. Belder, M. Ludwig, L. W. Wang, M. T. Reetz Angew. Chem. Int. Ed. 2006, 45, 2463-2466. 3. I. R. Baxendale, J. Deeley, C. M. Griffiths-Jones, S. V. Ley, S. Saaby, G. K. Tranmer Chem. Commun. 2006, 24, 2566-2668; I. R. Baxendale, C. M. Griffiths-Jones, S. V. Ley, G. K. Tranmer Synlett. 2006, 427-430. 4. G. L’Abbe Chem. Rev. 1969, 69, 345-363. 5. A. Aota, M. Nonaka, A. Hibara, T. Kitamori Angew. Chem. It. Ed. 2007, 46, 878-880. 6. T. Maruyama, H. Matsushita, J-i. Uchida, F. Kubota, N. Kamiya, M. Goto Anal. Chem. 2002, 76, 4495-4500; M. Tokeshi, T. Minagawa, K. J. Chromatogr. A 2000, 894, 19-23. 7. E. Kolehmainen and I. Turunen Chem. Eng. Process. 2007, 46, 834–839; C. H. Hornung, M. R. Mackley,I. R. Baxendale and S. V. Ley Org. Procecc Res. Dev. 2007, 11, 399–405; O. K. Castell, C. J. Allender and D. A. Barrow Lab Chip 2009, 9, 388–396; 8. E. Perperi, Y. L. Huang, P. Angeli, G. Manos and D. J. Cole-Hamilton J. Mol. Catal. A: Chem. 2004, 221, 19–27; E. L. Teo, G. K. Chuah, A. R. J. Huguet, S. Jaenicke, G. Pande, Y. Z. Zhu Catal. Today 2004, 97, 263–270; J. F. B. Hall, X. Han, M. Poliakoff, R. A. Bourne and M. W. George Chem. Commun. 2012, 48, 3073–3075. * Hemantkumar R. Sahoo, Jason G. Kralj, Klavs F. Jensen. Angewandte Chemie International Edition 2007, 46, 5704-5708 BIBL IOGRAPHY 43 Chimica Oggi - Chemistry Today - vol. 36(1) January/February 2018 KEYWORDS Surface-tension micro-extractor, liquid-liquid extraction, gas-liquid extraction, in-line extraction

RkJQdWJsaXNoZXIy MTY5Njg=