CO1_2020

59 Chimica Oggi - Chemistry Today - vol. 38(1) January/February 2020 give too broad a scope to the notion of “legitimate reasons for the non-use of the mark” (see, for analogy, judgment of 14 June 2007, Häupl, C - 246/05, EU: C: 2007: 340, paragraph 51). On the other hand, re-filling a trademark application, when there is doubt that previous registrations of the same trademark could be revoked for non-use, may also cause owner an accusation of bad faith. Indeed, in the EUIPO Guidelines for examination of MUEs it said: Bad faith has been found where an EUTM owner tries to artificially extend the grace period for non-use, for example by filing a repeat application of an earlier EUTM in order to avoid the loss of a right as a result of non-use (7). Therefore, the timing for filing an application for a trademark (TA) has to be wisely chosen in the case of a pharmaceutical product. Trying to draw a lesson from the Viridis judgment, it may be prudent to wait at least until the filing of the corresponding marketing authorization application (MAA), if there is a reasonable expectation that the corresponding drug could reach the market in five years from the trademark registration. REFERENCES 1. http://curia.europa.eu/juris/document/document.jsf?text=&doci d=215761&pageIndex=0&doclang=IT&mode=lst&dir=&occ=first& part=1&cid=1638024 2. decision of the Fifth Board of Appeal of the European Union Office for Intellectual Property (EUIPO) of 29 February 2016 (case R 2837 / 2014-5) 3. Regulation (EC) No 207/200, Article 51(1), Grounds for revocation 4. Articolo 24 comma 1, CPI: “A pena di decadenza il marchio deve formare oggetto di uso effettivo da parte del titolare o con il suo consenso, per i prodotti o servizi per i quali è stato registrato, entro cinque anni dalla registrazione, e tale uso non deve essere sospeso per un periodo ininterrotto di cinque anni, salvo che il mancato uso non sia giustificato da un motivo legittimo.” 5. Articolo 121 comma 1, CPI: “L’onere di provare la nullità o la decadenza del titolo di proprietà industriale incombe in ogni caso a chi impugna il titolo” / “In any case, the burden of proving the nullity or forfeiture of the industrial property title lies with the person contesting the title”. 6. DIRECTIVE (EU) 2015/2436 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 December 2015 to approximate the laws of the Member States relating to trademarks https://eur-lex.europa . eu/legal-content/EN/TXT/PDF/?uri=CELEX:32015L2436&from=EN 7. Guidelines for examination of MUEs, EUIPO, Part D, Section 2, Paragraph 3.3.2.1- Factors likely to indicate the existence of bad faith (Article 59(1)(b) EUTMR). INTELLECTUAL PROPERTY COLUMN FLOW DETECTOR MONITORS DISPERSION IN REAL TIME Uniqsis reports on how its Flow-UV™ inline UV-Visible spectrometer sets a new benchmark for real-time dispersion and nanoparticle distribution and agglomeration experiments. Designed for use with almost any commercially available flow chemistry system, Flow-UV™ allows dispersion experiments to be monitored in real time so that product collection can be controlled according to the onset and decline of steady-state conditions. It also provides a useful indication that steady state is maintained consistently throughout a continuous flow-through process. UV-Visible measurements can also be particularly significant for nanoparticle distribution and provide information about particle size and whether agglomeration is occurring. Compact and with no moving parts, the highly reliable Flow-UV™ fits conveniently into even crowded fume cupboards and does not require calibration routine servicing. In contrast to conventional Deuterium lamps, the Flow-UV™ uses a Xenon flash lamp source which has a lifetime of up to 10 years in normal use. Fibre optic waveguides connect the Flow-UV™ flow cell to the source and detector thereby permitting the flow cell to be positioned virtually anywhere in the flow path. The flow cell itself utilises a short length of PFA reactor tubing and is therefore not restricted to being located after the outlet back pressure regulator in the low-pressure region of the flow path where outgassing can be problematic. Flow-UV™ has been designed to be extremely easy to use. To assure linearity of response, Flow- UV™ offers users the ability to select up to five wavelengths over which to monitor a reaction, so helping to avoid detector saturation. Absorbance is plotted against time using the system control software. The control software can be configured to automatically record a background spectrum at the beginning of each experiment. Having previously set up and saved a method, pressing a single button is all that is required to start acquisition. http://www.uniqsis.com/paProductsDetail. aspx?ID=Flow-UV NEWS Monitoring dispersion and steady state in real time Flow-UV™ inline UV- Visible spectrometer

RkJQdWJsaXNoZXIy MTY5Njg=