CO2_2024

especially in the upstream space, Raman has proven its suitability – even for challenging tasks such as identifying specific metabolites or monitoring the glycoform distribution – and support exists in the form of specialized chemometric experts, reducing the initial effort for implementation. PAT AND THE FACILITY OF THE FUTURE The use of PAT tools sets the foundation not only for a thorough understanding and control of the process, but also for a seamless transition to Biopharma 4.0 realizing fully automated, self-monitoring and autonomously regulated, continuous bioprocesses in a facility of the future. Such a setup will collect real-time data and make appropriate adjustments across the entire process, e.g. by adjusting downstream methods according to the measured CPPs in the upstream process step. In short, implementation of the PAT framework is the basis of a dynamic, future-ready, and more efficient manufacturing process. However, the adoption pace in the biopharma sector is relatively slow, primarily due to specific challenges that must be addressed on the path toward the facility of the future. Overcoming these challenges requires transitioning existing analytical technologies to in-line or on-line operations. This involves developing fit-for-purpose solutions that are compatible with the PAT framework and complex biopharmaceutical processes. For example, additional development in the area of real-time product release and biosafety analysis is particularly crucial to reduce the lag times associated with cell-based assays or bioburden, mycoplasma, and endotoxin testing. Furthermore, establishing appropriate analytical techniques and suitable methods and models for data evaluation is key. Limited process understanding and a lack of expertise in continuous processes or PAT models can pose challenges during PAT implementation in biomanufacturing sites, leading to hesitation in relying on PAT for integrity or release testing. In this context, suppliers of PAT analytical instruments become invaluable partners to biopharmaceutical manufacturers. Leveraging their profound understanding of process needs and analytical capabilities, these suppliers can offer support by providing or developing appropriate models, thereby guiding and expediting PAT adoption. Having access to chemometric experts makes PAT implementation significantly faster and more convenient, especially if the support extends to streamlining the entire process. REFERENCES AND NOTES 1. Food and Drug Administration (FDA). Pharmaceutical Quality for the 21st Century - A Risk-Based Approach Progress Report. 2007. 2. International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). ICH Harmonised Tripartite Guideline: Pharmaceutical Development Q8(R2). 2009. 3. International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). ICH Harmonised Tripartite Guideline: Pharmaceutical Quality System Q10. 2008. 4. International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). ICH Harmonised Guideline: Quality Risk Management Q9(R1). 2023. 5. International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). ICH Harmonized Guideline: Continuous Manufacturing of Drug Substances and Drug Products Q13. 2022. 6. Food and Drug Administration (FDA). Guidance for Industry: PAT — A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance. September 2004. 7. Gerzon G, Sheng Y, Kirkitadze M. Process Analytical Technologies – Advances in bioprocess integration and future perspectives. Journal of Pharmaceutical and Biomedical Analysis. 2022;207:114379. 8. De Beer T, Burggraeve A, Fonteyne M, Saerens L, Remon JP, Vervaet C. Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes. International Journal of Pharmaceutics. 2011;417(1):32-47. 9. Esmonde-White KA, Cuellar M, Lewis IR. The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing. Analytical and bioanalytical chemistry. 2022;414(2):969-91. 10. Esmonde-White KA, Cuellar M, Lewis IR. The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing. Analytical and bioanalytical chemistry. 2022;414(2):969-91. 11. Schwarz H, Mäkinen ME, Castan A, Chotteau V. Monitoring of amino acids and antibody N-glycosylation in high cell density perfusion culture based on Raman spectroscopy. Biochemical Engineering Journal. 2022;182:108426. 12. Webster TA, Hadley BC, Dickson M, Busa JK, Jaques C, Mason C. Feedback control of two supplemental feeds during fed-batch culture on a platform process using inline Raman models for glucose and phenylalanine concentration. Bioprocess and Biosystems Engineering. 2021;44(1):127-40. 13. Lin YK, Leong HY, Ling TC, Lin D-Q, Yao S-J. Raman spectroscopy as process analytical tool in downstream processing of biotechnology. Chinese Journal of Chemical Engineering. 2021;30:204-11. Stacy Shollenberger holds an MS degree in biochemistry from the University of Virginia and an MBA from Penn State University. She has 15 years of experience in analytical and bioanalytical product and method development. Currently, Stacy is a Senior Manager of Process Analytical Technologies (PAT) at Merck KGaA, Darmstadt, Germany and is responsible for defining the PAT strategy to move testing from traditional off-line quality control (QC) to QC on the bioprocessing floor. ABOUT THE AUTHOR 35 Chimica Oggi - Chemistry Today vol. 42(2) 2024

RkJQdWJsaXNoZXIy MTY5Njg=