elution is preferred in Prep. Converting the gradient to isocratic provides an amazing opportunity for solvent recycling and a shorter cycle time. This means that the same eluent must be used for the feed to simplify the solvent mix to recycle. This can pose some challenges as solubility is an issue that affects the separation throughput. Assessing strongly adsorbed impurities is important as they can affect column performance by gradually degrading the separation capacity. Using isocratic elution also favors solvent composition control using PAT solutions (capacitance probe, Near IR, density, pH…). Unfortunately, not all processes can be converted to isocratic (oligonucleotides, peptides, biologics for example) and solvent usage will remain an issue, but more complex chromatographic separation solutions can be explored (SMB, CSSR, MCSGP, twin columns…). While reverse phase chromatography (i.e. aqueous mobile phase) is usually preferred for analytical, developing a normal phase process (i.e. mixture of organic solvents) is preferred for Prep. This offers more favorable solvent recycling options and an easier transition to the next synthesis step. Figure 1. Stacked injection chromatography. Figure 2. Steady state recycling internal profile (Figure from [7]).