The development of biologics, like monoclonal antibodies (mAbs), Antibody-drug conjugates (ADCs) and bispecific antibodies, has provided treatment for diseases once deemed untreatable, such as advanced cancers and autoimmune disorders. As powerful as these biologics are, their development still come with substantial technical challenges. Behind every biologic drug is a formulation that ensures the molecule’s stability, safety and efficacy. This unassuming yet critical component must handle the inherent complexity of biologics and their sensitivity to environmental factors like pH and temperature, while maintaining efficacy and manufacturability at scale. Increasingly, formulation efforts also address a key patient-centric need: transitioning therapies from intravenous (IV) to subcutaneous (SC) formats. High-concentration formulations are central to SC delivery, but they introduce new technical hurdles that demand a great deal of expertise. ABSTRACT KEYWORDS: Formulation; biologics; antibodies; conjugates; bispecific; intravenous; subcutaneous; viscosity; stability. Concentration and complexity: how formulation is the lynchpin for biologic development WILLIAM (BILL) MCDOWELL Senior Director of Analytics, Abzena, San Diego, USA Drug Formulation Development nentially with protein concentration. This elevated viscosity presents challenges for drug delivery, as it can exceed the capabilities of standard SC injection devices like autoinjectors. In addition, this impact on injectability can be complicated by the non-Newtonian behavior demonstrated by biologics at high concentrations. High-concentration formulations The growing need for high-concentration biologics stems from patient-centric demands for SC delivery, which Challenges in biologic drug formulation Physicochemical complexities Biologics are inherently sensitive to their environment due to their large, complex molecular structures. Changes in temperature, pH and mechanical agitation can destabilize these molecules, leading to aggregation, degradation or precipitation. These issues can cause irreversible damage to the product with a subsequent loss of therapeutic efficacy or inducing adverse effects in patients. Aggregation remains one of the most common challenges in biologic formulation. Aggregation not only reduces the potency of the biologic but also poses a significant risk of triggering adverse immune reactions. These aggregates often form due to weak intermolecular forces that become pronounced during storage or under stress conditions such as agitation during transport or freeze-thaw cycles. Another issue is viscosity. At higher concentrations – often required for SC delivery – viscosity can increase expoChimica Oggi - Chemistry Today Chimica Oggi - Chemistry Today vol. 43(2) 2025 vol. 43(2) 2025 26 27 offers greater convenience compared to IV administration – patients can self-administer in the comfort of their own homes, and do not require a hospital bed and medical staff to receive their treatment.High-concentration formulations allow for smaller injection volumes, but this comes with its own technical challenges. At higher concentrations, biologics often exhibit increased viscosity due to protein-protein interactions. These interactions make injection difficult and can also contribute to instability, leading to aggregation, precipitation or gelation during storage. Such behaviors are particularly pronounced in ADCs and multispecific antibodies, where different structural domains may interact unfavorably under the same formulation conditions. For instance, stabilizing a monoclonal antibody (mAb) could compromise the chemical stability of its linker-payload system if done incorrectly. High concentrations also exacerbate opalescence and particle formation, which need to be addressed to meet regulatory requirements. The challenge is not only in identifying these issues but also in resolving them without compromising the biologic’s safety, efficacy or manufacturability. Advanced analytics and innovative approaches are essential to overcome these hurdles. Manufacturing and scalability Once a biologic formulation is optimized, scaling up to commercial manufacturing presents another set of challenges. High-concentration formulations must retain their stability and consistency across large-scale production batches. Aggregation, viscosity, and phase separation tendencies can intensify during manufacturing processes such as mixing, filtration, and filling. Moreover, these formulations often require highly specialized equipment and expertise. SC biologics, for example, must be compatible with autoinjector devices, which necessitate tight control over viscosity and injectability. Regulatory demands for stability testing, shelf-life validation and cold chain logistics add further complexity, particularly for global distribution. Overcoming these challenges Advanced analytical tools Advanced analytics underpin successful formulation development. Techniques such as size exclusion chromatography (SEC), differential light scattering (DLS), and imaged capillary isoelectric focusing (icIEF) can be used to help understand and resolve stability issues. These methods allow researchers to monitor aggregation, viscosity and protein behavior under stress conditions, giving them the ability to fine-tune formulations to meet clinical and regulatory requirements. Delivery systems New delivery systems, such as lipid nanoparticles (LNPs) and polymer-lipid hybrids, are proving popular for biologics. LNPs protect sensitive biologics from degradation and enhance solubility while offering controlled release profiles. Polymer-lipid hybrids offer a balance of stability and biocompatibility, allowing targeted delivery and improved drug performance. Overcoming viscosity challenges Excipient screening plays a major role in reducing viscosity while maintaining protein stability. For example, viscosity-reducing agents must be carefully studied to avoid destabilizing intermolecular interactions critical for maintaining biologic integrity. A systematic approach to excipient selection ensures injectability without compromising longterm stability. Case studies Managing high viscosity for subcutaneous injection A customer had developed a mAb formulation that performed well in Phase I clinical trials but needed to transition from IV to SC administration for subsequent clinical studies and commercialization. The target concentration was 150 mg/mL, which, while being stable, significantly exceeded the viscosity limit for SC injection devices (20 cP). At this concentration, the formulation exhibited a viscosity of 34 cP, making it unsuitable for use with standard SC delivery devices. To address this, the formulation team undertook a screening process to identify viscosity-reducing excipients. Several buffers were tested to determine their impact on viscosity without compromising stability. This process revealed an excipient that reduced viscosity to within the acceptable range for SC injection while maintaining the biologic’s stability. Stress testing confirmed that the selected excipient did not introduce instability. In fact, it marginally improved the protein’s resistance to aggregation under accelerated conditions. The reformulated product successfully met all requirements for SC delivery and progressed to clinical studies. Improving solubility and stability Another customer presented a novel mAb that had been developed at a different CDMO. The formulation exhibited phase separation and gelation during refrigerated storage, which resolved upon warming to room temperature. While this behavior did not immediately affect the biologic’s quality, it posed significant regulatory challenges and raised concerns about usability in clinical and commercial settings. This problem came from the fact that the fundamental properties of the mAb had not been assessed during pre-formulation. The formulation team designed a study to investigate the underlying causes of these issues. They evaluated critical factors such as pH, ionic strength and excipient compatibility. Through this analysis, the team identified that the original formulation’s ionic environment was unsuitable for the mAb’s physicochemical properties. Adjustments to the buffer system improved solubility and eliminated the phase separation issue. The optimized formulation demonstrated long-term stability, remaining clear and free of visible particles after six months of storage at 2–8°C. Additionally, the reformulation allowed the biologic’s concentration to increase from 50 mg/mL to 100 mg/mL, meeting the customer’s clinical requirements. Trends driving the future of biologic formulation High-concentration biologics for subcutaneous delivery The shift toward high-concentration biologics reflects the increasing need for therapies that align with patient convenience and clinical practicality.
RkJQdWJsaXNoZXIy MTY5Njg=