Stage 3 has a higher risk component to it. CV (i.e., creation, execution, and approval) is a very visible process to the site. This means (especially execution) everything is performed with care and diligence, even the cleaning of equipment. Over time, cleaning can lose that focus. Therefore, it is important to create a robust and thorough stage 3 program. Per (3), (6), (10), (9), (1), there is an expectation to routinely monitor validated cleaning processes. PC Per (13), (14), analytical testing is expected at each changeover unless there is a justification via Quality risk management (QRM) process in place. The assessment should at a minimum consider cleaning reproducibility, product hazard, and possibility of visibly detecting residue below the HBEL. Most likely for HPAPI manufacturing, HBEL value will be too low to detect visually. A RA is still important because it can determine the level of testing (i.e., rinse and swab or just rinse). Swabbing can also be broken down into swabbing the same locations performed during CV or just the hard-to-clean locations. The RA can also differentiate requirements for different manufacturing processes and areas, depending on risk. An obvious question comes to mind. Why is PM and trending the cleaning parameters required, if the highest risk (i.e., PC) of cross contamination is always being tested? The reason is because PM and cleaning parameter trending confirm the cleaning process is still operating as validated. The PC testing is just a verification of that cleaning event. Though, the PC testing can be leveraged in the PM frequency RA to reduce the frequency and even type of testing between the same products. Process Consistency, Capability and Control A process in control will meet its cleaning residue limits consistently. A successful CV provides a statement of process consistency when an adequate number of trials were performed. The additional data collected during PM can establish appropriate limits (i.e., alert and alarm). In HPAPI, the distance between the safety limit and PM points (margin of safety) may be too small to incorporate alert and alarm limits. The process capability can be adapted as an index to measure cleaning process performance against the SL, which is considered the upper side of the specification (upper process capability index (Cpu)) (12). Cpu = Cleaning Limit – Average of data sample 3*SDEV of data sample Monitor the process to confirm the cleaning process remains in control. (12) is an excellent resource and guide for creating a cleaning process parameter trending program. PM Frequency PM is performed to demonstrate the process remains in a state of control (3). The frequency and type of testing should be determined by QRM principals. It can include a number of activities (3) such as: • Data analysis • Additional cleaning verification studies • Rinse sample analysis Though, rinse sample analysis can help monitor the cleaning process it does not eliminate the need for cleaning verification, which is a more in-depth analysis (3). Areas of special concern are (3): • Low HBEL value products • Products were HBEL derived residue cannot not be visually achieved • Equipment and products with history of failing cleaning • Highly variable testing results during verification and validation • Manual cleaning processes • Hard to clean location or surfaces • Equipment not accessible for visual inspection PM sampling locations Unless justified via a RA, PM testing and locations should be identical as what was required for CV. Periodic review (PR) PR schedule should be determined via a science and risk-based approach. Best practice is to include deviations, change management, CV procedure/requirement changes review, and cleaning parameter verification (verify validated parameters are still in effect) at some science and risk-based interval. To reduce number of documents and optimize the reporting process, consider including the PR reporting into the annual PM summary report. Deviations No additional considerations because the deviation process considers risk to patient safety and product. Change Management No additional considerations because the change management process should consider risk to patient safety and product. CONCLUSION In conclusion, there are no additional Stage 2 and Stage 3 requirements for HPAPI manufacturing, but additional steps such as steps or activities discussed in this article should be considered due to the high risk in HPAPI manufacturing. REFERENCES AND NOTES 1. APIC Guidance on Aspects of Cleaning Validation in Active Pharmaceutical Ingredient Plants, Active Pharmaceutical ingredients Committee (APIC), February 2021. 2. F. Ohsiek, HPAPI cleaning validation considerations – Part 1, Chimica Oggi - Chemistry Vol 41(1), January/February 2023 3. Canada Health Products and Food Branch Inspectorate Guidance Document: Cleaning Validation Guidelines GUIDE-0028, June 2021, https://www.canada.ca/en/ Chimica Oggi - Chemistry Today 24 vol. 41(2) 2023
RkJQdWJsaXNoZXIy MTY5Njg=