DPTE® TECHNOLOGY The first secure transfer system was developed in 1963 by La Calhene (now Getinge) and was named “DPTE®” Double Porte pour Transfert Étanche (Double Door for Sealed Transfer). This type of rapid transfer port (RTP) was developed initially for use in the French nuclear industry for the safe transfer of radioactive materials. However, its potential as an effective containment device was quickly realised and it was adapted to facilitate the safe transfer into and out of isolators for various sterile and toxic applications. It is recognised as a successful industry standard for transfer systems with around 40, 000 units in use around the world (Getinge) (1). CONTAINMENT PERFORMANCE ASSESSMENT OF DPTE - OVERVIEW Getinge’s DPTE Alpha ports (Figure 1) represent a well-known, respected and widely used containment device within the pharmaceutical industry. However, there is little substantial data available in the public domain indicating the containment performance of these devices to demonstrate their suitability for making contained transfers, into and out of isolators, when handling potent, or highly potent API’s. SafeBridge were commissioned by Getinge to conduct a containment performance assessment of the four available DPTE Alpha ports. Each of the different sized Getinge DPTE Alpha ports available were assessed; 105 mm, 190 mm, 270 mm and 350 mm diameter. Depending on the specific pharmaceutical application, the DPTE Alpha port could be subjected to consecutive connections and disconnections. Determining whether repeated connections and disconnections to a DPTE Alpha port affected its containment performance was therefore included as part of the assessment criteria. The containment performance of each of the four DPTE Alpha ports was therefore assessed after one connection and disconnection of a DPTE- BetaBag or DPTE Beta Container, then after five and then ten connections and disconnections, carried out in succession. The purpose of the containment performance assessment was to quantify the effectiveness of the DPTE Alpha transfer device in preventing emissions of powdered API during a transfer task. This was assessed on an isolator while handling a low toxicity (surrogate) powder, using proximate area samples (primarily) and personal samples. Proximate samples were positioned around the equipment at close proximity to the target area, at locations that are considered potential leakage points. Personal samples were positioned within 30 cm of the operator’s breathing zone, to reflect the concentration of API around the equipment during the range of individual tasks carried out during the process. The airborne concentrations recorded were averaged over the task period and used to indicate the containment performance of the devices. This is different than assessing employee personal exposures in the workplace against occupational exposure limits (OELs) (2). Personal samples are taken within the breathing zone of the employee and are the primary indicator for assessing personal exposure. In that case, the airborne concentrations recorded are normally averaged over eight hours before a comparison is made to the limit value. The challenge was to assess the effectiveness of the DPTE Alpha port alone when removing the DPTEBetaBag or DPTE Beta Container, as well as ensuring that the necessary opening of the isolator to change between different sized Alpha ports did not result in emissions of API. RESULTS ANALYSIS AND INTERPRETATION For this assessment airborne acetaminophen that might be released during the DPTE use was quantified by drawing air into sampling heads with volumetric flow of 2.0 litres per minute. The IOM filter cassette samples were analysed by the SafeBridge AIHA accredited analytical laboratory, applying the validated method, using HPLC and electrochemical detection. Surface samples were collected using polyester swabs. Samples were also analysed using this internal method. This extremely sensitive analytical method allowed detection down to less than 1 ng/ m3 per sample for air samples and less than 1 ng per cm2 for surface samples. PRELIMINARY WORK: CONTAINMENT VERIFICATION OF PROPOSED ISOLATOR This complex assessment required extensive preliminary work to assess whether external sources of airborne surrogate would interfere with the DPTE Alpha port containment performance assessment. The preliminary work had two main objectives; the first was to assess the likelihood of external airborne contamination affecting the containment performance assessment of the DPTE Alpha ports, the second was to assess the potential for airborne and surface contamination to occur when changing the diameter of the DPTE Alpha port aperture prior to undertaking the next assessment scenario. 23 Chimica Oggi - Chemistry Today vol. 42(2) 2024 Figure 1. Getinge DPTE® Alpha port.
RkJQdWJsaXNoZXIy MTY5Njg=