containment performance assessment for each of the four different sized DPTE Alpha ports, after one, five and ten connections and disconnections. Samples were collected before each test run to quantify the contamination present, if any, on the ring of concern prior to the DPTE containment performance assessment. RESULTS SUMMARY FOR AIR CONCENTRATIONS The results of the assessments, conducted during connection and disconnection of the various DPTE devices, demonstrated excellent containment performance, and based on the parameters adopted in this assessment indicated that the containment performance of each of the four DPTE Alpha ports does not significantly change after one, five and ten connections of a DPTE-BetaBag or DPTE Beta Container. The concentrations recorded on all samples were all averaged over the task period and used to determine the DPTE Alpha port containment performance. The airborne concentrations recorded on the proximate area samples adjacent to the DPTE Alpha ports were all less than 1.2 ng/m3, and of the 108 proximate area samples, 96% were below the limit of quantification for the analytical method used. The airborne concentrations recorded on the personal samples during the final disconnection of the DPTE Alpha port was between <1.5 – 36 ng/m3, the other detectable value recorded was 2.5 ng/ m3. Out of the 36 personal samples, 94% were below the limit of quantification for the analytical method used. These results demonstrate the suitability of all the different sized Getinge DPTE transfer devices when working with highly potent pharmaceutical active ingredients. RESULTS SUMMARY FOR SURFACE CONCENTRATIONS The surface concentrations recorded on the ring of concern of the DPTE Alpha ports were all between <0.1– 72 ng per cm2, and of the surface samples taken, 75% (9 out of 12) were below the value of 10 ng per cm2. CONCLUSIONS The containment performance of four different sized Getinge DPTE Alpha ports has been reliably assessed and the data indicates their suitability as contained transfer devices when handling potent and highly potent pharmaceuticals. In addition, the containment performance of each of the four DPTE Alpha ports does not significantly change after one, five and ten connections and disconnections of a DPTE- BetaBag or DPTE Beta Container. It appears that very small quantities of powder are being transferred onto the peripheral band on the lip seal (ring of concern) of the DPTE Alpha port during connection and disconnection of a DPTE- BetaBag or DPTE Beta Container. Cleaning the ring of concern following removal of the device, is therefore essential to maximize the performance of these devices and should be considered part of the end user’s operating procedure. LIMITATIONS Due to the inherent variability of airborne particulate data generated when assessing the containment capabilities of pharmaceutical equipment, it is recommended that a statistical approach is applied to data interpretation prior to comparison with limit values. REFERENCES AND NOTES 1. Getinge, DPTE Alpha Port. 2. M. W. Axon, J. Ball, and E. V. Strijdonck.,” Containment Performance of Semi-continuous Tablet Coating Equipment ”, Chemistry Today, Vol. 38 (6), 2020, pp 45-49. 3. International Society for Pharmaceutical Engineering, “Assessing the Particulate Containment Performance of Pharmaceutical Equipment”, ISPE Good Practice Guide, ISPE, 2nd Edition (2012). Chimica Oggi - Chemistry Today 26 vol. 42(2) 2024 James Ball is a Senior Occupational Hygiene Consultant for SafeBridge Europe; he is a Licentiate Member of the British Faculty of Occupational Hygiene. He holds a master’s degree in Environmental Health and a Bachelor of Science degree in Applied Biology. James has over 10 years’ experience working in occupational hygiene, he has previously held positions as a site Occupational Hygienist and as a Global Occupational Hygienist. SafeBridge Europe is a global supplier of occupational health services to the pharmaceutical industry, specialising in safe handling of potent pharmaceutical actives. ABOUT THE AUTHORS Cyril Mounier is a solution owner – Pharmaceutical application specialist for Getinge Life Science France. He holds a license’s degree in chemistry. Cyril has over 20 years’ experience working in isolation technologies and transfer systems. He has previously held different positions as qualification/validation manager and then as an expert of the Getinge products, their use and their validation. Getinge Life Science France is a global provider of transfer solutions to the pharmaceutical industry as well as for operator protection in the nuclear business. The transfer solutions are used in sterile and toxic applications protecting either the products and/or the operators.
RkJQdWJsaXNoZXIy MTY5Njg=