The surface sample results inside the left chamber (for all three test runs) ranged between 0.0034 -0.15 µg per cm2, with the surface concentrations decreasing per test run, indicating that the level of cleaning was improving with practice. The surface concentrations recorded in the right chamber (for all three test runs) after changing of the DPTE and cleaning the surfaces ranged from 0.0016 – 0.12 ng per cm2. The air samples taken inside the right chamber after at least 12 hours following the DPTE Alpha port change over, were all below the limit of quantification for the analytical method. These results provided confidence that any residual surface contamination present was unlikely to become airborne and interfere with the next assessment. CONDUCTING CONTAINMENT PERFORMANCE ASSESSMENTS ON DPTE ALPHA PORTS To assess the containment performance of the DPTE Alpha port, a suitable and easily repeatable task was required to challenge the device. This was achieved by subjecting one chamber of a two-chamber isolator, which housed a DPTE Alpha port on the dividing wall to an internal airborne concentration of surrogate. This was accomplished by transferring a small quantity (500 g) of surrogate powder (acetaminophen), from one container to another using a spoon. The left chamber had an approximate internal volume of 0.5 m3, it was closed and operated at -120 Pa. The right chamber had an approximate internal volume of 0.8 m3, its front window was left open for access purposes. In between the left and right chamber was a hinged stainless-steel door that housed the DPTE Alpha port. This retractable stainless-steel door was secured in place by an inflatable seal. The middle section of the door featured an interchangeable steel plate which accommodated specific sizes of DPTE Alpha port (105, 190, 270 and 350 mm). To quantify airborne emissions of surrogate from the DPTE Alpha port after disconnection of a DPTE- BetaBag or DPTE Beta Container, three air samples were placed at close proximity around the DPTE Alpha port (right chamber); one at the top center, one at the bottom right position and one at the bottom left position. Two personal air samples were also taken to assess personal exposures during the containment performance assessment, one during surrogate manipulation in the left chamber and any connections and disconnections of the DPTE- BetaBag® or DPTE Beta Container (all samples ran for approximately 25 minutes) and one during the final disconnection to help identify when and where any exposure might be occurring (all these samples ran for 15 minutes). The sample positions were chosen based on guidance available in Appendix 1, Protocol 1 of the ISPE guide (2). For each of the four different diameter DPTE Alpha ports assessed, three scenarios were performed: • containment performance during one connection and disconnection (Figure 4) • containment performance following five connections and disconnections • containment performance following ten connections and disconnections When a DPTE Alpha ports was being assessed after ten connections and disconnections for example, the DPTE- BetaBag or DPTE Beta Container, was connected and disconnected nine times in quick succession to the DPTE Alpha port (opening the internal Alpha door each time). Finally, the DPTE- BetaBag® was connected for the fifth time or tenth time and then left in position (with the internal Alpha door open) during the transferring of 500 g of surrogate powder, from one container to another. Three test runs were performed to assess each of these three separate connection and disconnection scenarios. Therefore, nine test runs were performed for each size DPTE Alpha port and thirty-six test runs were performed over a ten-day period, with a total of 270 air samples collected. After each DPTE Alpha port had been subjected to the three scenarios, the DPTE Alpha port was changed to the next aperture size using the validated methodology explained previously in the preliminary work section. SURFACE SAMPLING AND RING OF CONCERN The “ring of concern” is the generic term used to describe the area where an Alpha port door and the Beta assembly meet. This very small circular band on the lip seal is approximately 0.1 – 0.5 mm wide and is exposed to the inside of the isolator when the alpha door is opened. It can therefore potentially become contaminated with whatever is present inside the isolator chamber at the time of use, which in this case was the acetaminophen surrogate. Surface samples were collected from the ring of concern prior to and immediately after the first test run of the 25 Chimica Oggi - Chemistry Today vol. 42(2) 2024 Figure 4. Connection and disconnection of DPTE- BetaBag®.

RkJQdWJsaXNoZXIy MTY5Njg=