REGULATORY REQUIREMENTS FOR SYNTHETIC PEPTIDES Information in the European Pharmacopeia (EP) (1), as summarised in Table 1 highlights the required impurity control for synthetic peptides as they proceed through clinical development. In general terms, control of impurities should increase through clinical development. Specifically, individual impurities should not exceed their values as qualified in toxicological studies, or be greater than 1.0%, whichever is higher. However, these limits apply to a specific analytical method and as method development is performed, this can result in changes to the levels of impurities previously thought to be qualified. Hence, it is important to perform analytical development with this in mind, and ensure knowledge of the overall impurity profile of a product is understood right from the start. ANALYTICAL DEVELOPMENT AND IMPURITY DETECTION In analytical development, a screening approach is applied using material generated early in process development. Whilst no two peptide methods are alike, they typically encounter the same challenges: • Resolution • Purity of the main peak caused by co-eluting impurities • Methods with long run times and limited solution stability Screening, performed on an LC-MS instrument, takes ~3 days and results in the basis of the analytical method that will be further developed and validated. The mass spectrometry information allows the process and analytical teams to understand early if co-eluting impurities are present, which will be resolved analytically at a later date, and thus need control during the process development phase. PURIFICATION PROCESS DEVELOPMENT PART 1 – SCREENING FOR SELECTIVITY In a similar manner, purification process development also starts with a screening phase and will typically draw on the information gained in the analytical labs. Whilst the preparative chromatography used in manufacture will have a particle size of ~10µm due to the back pressure limitations of the equipment, screening is typically performed on smaller particle size columns. The main focus on this phase of work is to identify the conditions that offer the best selectivity, since this offers the single biggest opportunity for resolution, and thus impurity control, as shown in the equation below (2). Looking at each parameter in turn, it’s clear that selectivity (α in the equation above) is the predominant factor in terms of impurity resolution. Furthermore, increasing k (the capacity factor) requires an increase in solvent consumption and an increase in N (column efficiency) is impractical as this relies on a decrease in particle size out-with the limitations of the bulk media used for preparative chromatography. PREPARATIVE CHROMATOGRAPHY OF PEPTIDES AND OTHER LARGE MOLECULES STEVEN MCINTYRE Peptide Process Development Department Manager, Almac, Seagoe Industrial Estate, Craigavon, United Kingdom Over the last number of years, analytical technologies for assessing the purity of a synthetic peptide have changed significantly, with U(H)PLC methods utilising media with specific properties designed to separate peptide impurities used in almost all peptide analyses. Furthermore, additional scrutiny of these methods via mass spectrometry or ion mobility spectrometry ensures that all impurities produced during the manufacture of a peptide are now routinely detected. The use of preparative chromatography is still the main option for purification of peptides, a technology that has not quite advanced at the same rate, with 10µm C18 silica still the method of choice for most purifications. This paper will describe the holistic approach taken at Almac to ensure peptides and other large molecules produced for clinical and commercial purposes are still able to meet the stringent regulations and increased scrutiny. PREPARATIVE CHROMATOGRAPHY ABSTRACT KEYWORDS: • Peptide therapeutics • Process development • Preparative HPLC • Impurity control Chimica Oggi - Chemistry Today 42 vol. 42(2) 2024 Table 1. Limits for impurities in synthetic peptides as listed in EP (Table 2034.2). Figure 1. Equation for calculation of theoretical plate (separation efficiency).

RkJQdWJsaXNoZXIy MTY5Njg=