In order to screen for selectivity even for preparative chromatography, small U(H) PLC columns are used in an analytical setting, with up to 100 chromatograms generated within 24 hours. The media used in this screening phase is typically 1.7µm, but importantly is also available in bulk 10µm for manufacture. The typical parameters that are screened are media, buffer, pH and organic modifier. The chromatograms generated are assessed based on the following criteria, with an appropriate weighting applied to each: • Purity (lower is better) • Peak width (lower is better) • Retention factor of peak before main peak (higher is better) • Retention factor of peak after main peak (higher is better) The data is then sorted to provide a graphical output and allow selection of the optimum media and buffer for the next phase of development. PURIFICATION PROCESS DEVELOPMENT PART 2 – OPTIMISATION After selection of the best conditions for selectivity, attention switches to the optimisation of the purification method, now using 10µm bulk media. The output from a preparative HPLC step is usually a balance between purity, loading and recovery, particularly as most of the impurities generated in the manufacture of peptides have similar chromatographic properties. As can be seen in Figure 4, when incomplete impurity resolution is obtained, which is common in peptide purification, one can either pool all of the product containing fractions to increase the yield and lower the purity, or pool the fractions free from the impurity to get a higher purity but lower yield. Since purity is typically fixed for clinical and commercial peptides, yield is usually compromised. Newer technologies like multi-column counter-current solvent gradient purification (MCSGP) allow for the automated recycling of the mixed fractions which can increase the yield (3). Aside from having the optimum selectivity in purification, loading is another important factor that has a significant impact on purification. Considering Figure 4, increasing the loading can simply lead to more of an overlap of the impurity and product and hence no overall improvement. However, working with a low loading that improves separation can lead to an impractical chromatographic step in manufacture, potentially requiring hundreds of injections and weeks of manufacture time to purify a batch of crude peptide. Another key aspect in the optimisation of a purification method is the impact of pH and the potential for orthogonality that this brings. Preparative chromatography relies on significant overloading of the product onto the silica, resulting in isothermal behaviour which is either Langmurian or anti-Langmurian (4). The difference in this isothermal behaviour can be influenced by pH and can be exploited to aid with impurity removal. Figure 5 shows a plot of a peptide versus a key impurity during a purification of a peptide on C18 silica using 0.1% TFA as the modifier. At this pH (pH 2.5), a Langmurian isotherm is in operation leading to the tailing of the product peak. In this case, the impurity essentially elutes throughout the product elution making removal of it impossible. By switching the pH of the purification to ~ pH 5, the isothermal behaviour of the product changes to anti-Langmuarian, leading to a fronting peak. Since the impurity behaviour does not change significantly, removal of it is now possible (Figure 6). The final piece of optimisation typically involves the gradient. As in the loading, one can apply a very long, slow gradient to try and separate an impurity, but this can lead to an impractically long preparative purification. Typically, a purification run time should be one hour or less. 43 Chimica Oggi - Chemistry Today vol. 42(2) 2024 Figure 2. Summary of impact of main factors on impurity resolution. Figure 3. Screening chromatography assessment. Figure 4. Graphic showing impact of impurity resolution on purification yield.

RkJQdWJsaXNoZXIy MTY5Njg=