CO2_2024

PURIFICATION PROCESS DEVELOPMENT PART 3 – FINAL CHECKS The purpose of preparative chromatography is to deliver a peptide of appropriate quality suitable for either clinical or commercial supply. Even if a purification delivers the peptide of the desired quality in solution, things can still go wrong! In particular, hydrolysis of peptides containing a glutamine or asparagine in the sequence can undergo deamidation to form the corresponding glutamic acid or aspartic acid impurities, or peptides containing an Asp-Pro in the sequence can also undergo hydrolysis, which in either case can lead to a peptide failing specification if the rate of formation is not understood and controlled. Another aspect that must be controlled is the potential for a peptide to precipitate and/or aggregate in solution. One of the final steps in a peptide purification process is filtration of the final product solution through a 0.22µm filter to remove any bioburden present ahead of lyophilisation and packaging. If a peptide does precipitate from solution, this negates the possibility of performing this critical step and part of the process development phase is to ensure this does not happen under the parameters of the purification process. PURIFICATION SCALE-UP Process development of peptide purifications is performed in such a way that scale-up ought to be straightforward! The columns and media used in development mimic that to be used in manufacture with a fixed bed height , meaning the scale-up typically involves increasing the loading and liner flow-rate in line with the square of the radius of the column to be used. An example of this is shown below: As discussed in the previous section, the purification of large quantities of a crude peptide can run for up to 2 weeks and therefore it is critical that the stability data is understood to avoid degradation of the now purified peptide! PURIFICATION PROCESS VALIDATION As products move through clinical development and ahead of commercial supply, the process development team will challenge the purification step as part of readiness for process validation. This typically involves statistically designed experiments to determine both the normal operating ranges (NOR) and the proven acceptable ranges (PAR). The use of DoE allows for the interpolation of parameters that interact with each other and combine to create an effect on the purification performance, with an example shown in Figure 7. In this case, an impurity (RRT 0.967) has been demonstrated to be under full control within the parameters studied (TFA content of the crude peptide and TFA content of the aqueous buffer to be used in purification) with levels of the impurity only varying between 0.146% and 0.152% against a specification limit of 0.35%. As peptide purifications typically employ a number of repeat injections, this is also studied in development ahead of process validation to understand how many injections would be possible with a single charge of purification media, specifically looking at a change in column performance or significant impurity or product carryover between injections. LACK OF IMPURITY CONTROL IN PURIFICATION In some cases, despite best efforts in purification, an impurity may be impossible to control in purification and must be controlled at source. Hence, identification of which impurities this applies to in a peptide is critical information. An example where this has been performed is shown in Figure 8 below. Figure 5. Product versus Impurity elution at pH 2.5. Figure 6. Product versus Impurity elution at pH 5. Chimica Oggi - Chemistry Today 44 vol. 42(2) 2024

RkJQdWJsaXNoZXIy MTY5Njg=